Submitted by administrator on Wed, 03/04/2015 - 00:54
The capacity of the fuse on the circuit that controls the magnetic clutch for the air conditioner is inadequate, and therefore, when the coil for the magnetic clutch deteriorates causing excessive current in the circuit, the electrical relay for the air conditioner burns out, which in the worst case could result in a fire.
Case Number:
RJ-0592-0
Make/model:
Issued:
Thu, 1999-10-07
Component:
fuse
Affected:
8 853
Correction:
10A fuse should be additionally installed
Identification:
10A fuse on the wire
Vehicle:
Make:
Mazda
Type:
E-JC3S
Period:
N/A
Frame / Chassis No:
JC3S-100001..JC3S-100520
Make:
Mazda
Type:
E-JCES
Period:
N/A
Frame / Chassis No:
JCES-100001..JCES-100633
Make:
Eunos
Type:
E-JC3SE
Period:
N/A
Frame / Chassis No:
JC3SE-100016..JC3SE-120150
Make:
Eunos
Type:
E-JCESE
Period:
N/A
Frame / Chassis No:
JCESE-100034..JCESE-120084
unique_id_feeds: