Submitted by administrator on Wed, 03/04/2015 - 00:59
For the heat exchangers for heating air, the storage box structure does not provide a sufficient waterproofing function and allows water containing snow melting agent to seep through, which can cause an electric leakage around the harness connectors attached to the fan motors. If this problem is left unattended, the connectors may overheat, and in the worst case, a fire could break out.
Case Number:
RJ-2105-0
Make/model:
Issued:
Tue, 2008-04-15
Component:
heat exchanger for heating air
Affected:
906
Correction:
Seal adhesive should be additionally applied to the heat exchanger boxes, and the harness connectors and the drain outlets should be replaced with the factory approved replacement units. Also, the fan motors should be checked for rust, and rusty ones should be replaced with new ones. Incidentally, it is going to take some time to supply the factory approved replacement units, and therefore, as a temporary measure, the harness connectors should be cut off and the harnesses should be directly connected.
Identification:
yellow paint on the lower right of the name plate
Vehicle:
Make:
Isuzu
Type:
ADG-RU1ESAJ, PKG-RU1ESAJ
Period:
30/08/2005..25/03/2008
Frame / Chassis No:
RU1ESA-60011..RU1ESA-60832
Make:
Isuzu
Type:
ADG-RU8JHAJ, BDG-RU8JHAJ
Period:
14/02/2006..10/03/2008
Frame / Chassis No:
RU8JHA-60011..RU8JHA-60099
unique_id_feeds: