RJ-1552-0

For the printed circuit board located on the back of the combination meter, the activation circuit for the alternator is not well designed, and therefore, excessive stress may be put on it, due to thermal expansion of the printed circuit board, which is caused by temperature rise in the passenger compartment and/or heat generated by the meter. If such stress is repeatedly placed on the circuit, a disconnection may occur. If the circuit is disconnected, the alternator will not be activated at engine start, and in the worst case, the engine would stop while driving and would not restart.

Case Number: 
RJ-1552-0

Make/model:

Issued: 
Tue, 2005-11-15
Component: 
electrical equipment (printed circuit board for the combination meter)
Affected: 
69 635
Correction: 
The activation circuit for the alternator on the printed circuit board should be replaced with the factory approved replacement circuit.
Identification: 
white or yellow paint on the head of the upper bolt on the upper hinge of the right rear door
Vehicle: 
Make: 
Mitsubishi
Type: 
GF-CQ2A
Period: 
24/01/2001..05/09/2002
Frame / Chassis No: 
CQ2A-0200004..CQ2A-0214377
Make: 
Mitsubishi
Type: 
GF-CQ5A
Period: 
21/02/2000..19/02/2001
Frame / Chassis No: 
CQ5A-0000011..CQ5A-0000599
Make: 
Mitsubishi
Type: 
GF-CQ5A
Period: 
27/01/2001..24/07/2002
Frame / Chassis No: 
CQ5A-0100201..CQ5A-0100365
Make: 
Mitsubishi
Type: 
TA-CR6W
Period: 
04/07/2000..14/05/2002
Frame / Chassis No: 
CR6W-0000201..CR6W-0008184
Make: 
Mitsubishi
Type: 
GH-CR9W
Period: 
18/01/2000..27/07/2000
Frame / Chassis No: 
CR9W-0000026..CR9W-0027151
Make: 
Mitsubishi
Type: 
TA-CR9W
Period: 
04/07/2000..15/05/2002
Frame / Chassis No: 
CR9W-0100001..CR9W-0120511