Submitted by administrator on Wed, 03/04/2015 - 00:59
For the terminal of the electrical wiring connected to the alternator, oxidation may occur on the caulked joint due to the lack of adequate caulking, which could result in electrical disconnection. If this problem is left unattended, the engine will stall and fail to restart, as the battery will not be charged.
Case Number:
RJ-2141-0
Make/model:
Issued:
Thu, 2008-07-03
From:
2005-08-06
To:
2007-11-30
Component:
alternator (electrical wiring)
Affected:
245 165
Correction:
The terminal should be cut off, and the wiring should be completed with the factory approved terminal.
Identification:
The new terminal cap is grey, whereas the old one is black.
Reporting Company:
SUZUKI
Vehicle:
Make:
SUZUKI
Type:
EBD-DA64V
Period:
06/08/2005..30/11/2007
Frame / Chassis No:
DA64V-100072..DA64V-264888
Make:
SUZUKI
Type:
GBD-DA64V
Period:
24/08/2005..30/11/2007
Frame / Chassis No:
DA64V-600016..DA64V-743201
Make:
SUZUKI
Type:
ABA-DA64W
Period:
06/08/2005..30/11/2007
Frame / Chassis No:
DA64W-100098..DA64W-253881
Make:
MAZDA
Type:
EBD-DG64V
Period:
01/09/2005..30/11/2007
Frame / Chassis No:
DG64V-100002..DG64V-243074
Make:
MAZDA
Type:
GBD-DG64V
Period:
30/08/2005..29/11/2007
Frame / Chassis No:
DG64V-600001..DG64V-740076
Make:
MAZDA
Type:
ABA-DG64W
Period:
01/09/2005..30/11/2007
Frame / Chassis No:
DG64W-100002..DG64W-241269
unique_id_feeds:
136917