RJ-2467-0

On certain vehicles, rainwater can enter the blower fan motor due to the improper structure of the air intake of the air conditioner, and therefore, the motor bearing may become rusty and stuck, in which case the blower fan motor would cease to operate, causing the defroster to stop functioning. For the manual air conditioner, the fuse of the resistor that controls the blower fan revolutions may not meltdown, and in the worst case, a fire could break out.

Case Number: 
RJ-2467-0

Make/model:

Issued: 
Thu, 2010-02-25
From: 
2005-08-06
To: 
2009-10-29
Component: 
blower fan motor
Affected: 
432 366
Correction: 
The cover should be installed for the air intake. Also, the blower fan motor should be inspected, and if rust is found, it should be replaced with a new one. For the manual air conditioner, if rust is found, the resistor that controls the blower fan revolutions should be replaced with the factory approved replacement unit.
Identification: 
red sticker on the ID plate
Reporting Company: 
SUZUKI
Vehicle: 
Make: 
SUZUKI
Type: 
EBD-DA64V
Period: 
06/08/2005..29/10/2009
Frame / Chassis No: 
DA64V-100072..DA64V-378424
Make: 
SUZUKI
Type: 
GBD-DA64V
Period: 
24/08/2005..23/10/2009
Frame / Chassis No: 
DA64V-600016..DA64V-755360
Make: 
SUZUKI
Type: 
ABA-DA64W
Period: 
06/08/2005..23/10/2009
Frame / Chassis No: 
DA64W-100098..DA64W-334381
Make: 
MAZDA
Type: 
EBD-DG64V
Period: 
01/09/2005..23/10/2009
Frame / Chassis No: 
DG64V-100002..DG64V-301547
Make: 
MAZDA
Type: 
GBD-DG64V
Period: 
31/08/2005..22/10/2009
Frame / Chassis No: 
DG64V-600001..DG64V-750335
Make: 
MAZDA
Type: 
ABA-DG64W
Period: 
01/09/2005..22/10/2009
Frame / Chassis No: 
DG64W-100002..DG64W-294804
unique_id_feeds: 
136943